Phase II Sample Evaluation Sheets

Report No: 0112061 Test Date: 1/12/06
Sample Material: 1018 Steel Surface Finish: Machined
Customer Part#: n/a Test Method:Dynamic Hardness Testing
Company Name: AAA Mfg. Inspector:   N. Gitter

Results were achieved after multiple test groupings were performed on supplied samples. Leeb method converted to HRC scale


Model No. PHT-2500D

Portable Hardness Tester

Section Test #1 Test #2 Test #3 Average-HRC
1 46.6 46.9 46.5 46.7
2 45.8 46.2 46.2 46.1
3 46.5 46.5 46.8 46.6
4 46.8 46.5 46.5 46.6
5 46.5 46.5 46.0 46.3
6 46.2 46.5 46.5 46.4
7 46.5 46.0 46.0 46.1
8 45.8 46.5 46.5 46.2
9 46.2 46.8 46.5 46.5
10 46.2 45.9 46.2 46.1

This evaluation process is only intended to inform the prospective user of the capabilities and performance of above mentioned testing equipment on supplied test samples in a controlled environment. Results may vary based upon factual application, environment and product knowledge.