Metrology Material, Precision Measuring, Hardness Testers Phase II Plus Register
for
Free Catalog
21 Industrial Ave.
Upper Saddle River, NJ 07458
Phone: 201-962-7373
Toll Free: 800-526-9087
Fax: 201-962-8353

 
 
Coating Thickness Gauge
   

Simplicity in coating thickness measurement!

The PHASE II PTG-3500 coating thickness gauge can perform two different methods of calculating thickness measurement by utilizing the characteristics of both eddy current and magnetic induction.

Testing performance is both non-destructive and extremely accurate.

With this state of the art thickness gauge, you can easily detect the thickness of nonmagnetic coating on a magnetic substrate (ferrous) or an insulating coating on a non-magnetic conductive substrate (non-ferrous) utilizing either an integrated probe or our version that comes with 1 auto-detect external probe.

The PHASE II PTG-3500 can be used in many areas of industry including manufacturing, general engineering, commercial inspection, etc.


Main Technical Data
" Measuring range: 0-1000 m max. or 0-40 mils
" Resolution: 0.1 m / 0.01mils(0-99 m) or 1 m (over 100 m)
" Guaranteed tolerance:
After one-point calibration: +/- 1-3%n or 2 m (whichever is greater)
" Display: 4 digits (digit height = 10mm/0.4 )
" Min. measuring area: 0.2 x 0.2 (5mm x 5mm)
" Min. radius of curvature: Convex: 0.12 (3mm)
Concave: 1.2 (30mm)
" Min. substrate thickness: Ferrous: 20 mils (0.5mm)
Non-ferrous: 2 mils (50 m)
" Calibration: Zero Calibration
Foil calibration
" Max. Surface temperature of test object: 302 degrees F (contact time max is 2 seconds)
" Power source: 4 AA batteries
" Dimensions: 161 x 69 x 32mm
" Weight: 9oz. (260g)
 
Coating Paint Thickness Gauges
The PTG-3500 utilizes an integrated probe that can automatically detect a Ferrous or Non-Ferrous substrate and comes with 2 substrate samples (steel,aluminum), 4 calibrated thickness samples, carry case, batteries and operation manual.


Non-Destructive Coating Thickness Measuring Principles


1) Magnetic Induction Priciple:
The Phase II PTG series of Coating Thickness Gauges utilize this non-destructive priciple when measuring coatings on ferro-magnetic substrates such as Steel and Iron. The coatings must be non-magnetic such as; paint, enamel, aluminum, chrome, copper and brass.

2) Eddy-Current Priciple:
The Phase II PTG series of Coating Thickness Gauges utilize this non-destructive priciple when measuring coatings on non-magnetic substrates such as; Aluminum, Aluminum Alloys, bronze, copper, brass tin and rustproof weak magnetic steels. The coatings must be electrically insulating such as; paint, enamel, plastics, anodized coatings and ceramics.

Calibration Procedures
NOTE: All PTG series Coating Thickness Gauges are inspected and calibrated using the Two-Point Calibratiuon procedure prior to shipment.

1) One-Point Calibration:
This procedure is accomplished by  Zeroing the gauge on an uncoated version of the sample that you will be checking the coating thickness on. To accomplish this calibration, you will need to follow the simple calibration procedure that is explained in the operation manual. Although this is an accurate method for calibration, it is not as accurate as using the two point calibration.

2) Two-Point Calibration:
This procedure is accomplished by  zeroing the gauge on one of the supplied substrate samples (steel/aluminum) and then placing one of the calibrated  foils on that substrate and calibrating the gauge to match the known thickness of the foils. It is best to use the foil that is closest to the actual known thickness of your own samples to be tested. This is a very simple procedure that is explained in the operation manual. By using the two-point calibration procedure, you are making sure that the gauge will be at its most accurate when testing your own coated samples. This is the same method used to calibrate every gauge prior to shipment.

3) Frequency of Calibration:
Once the PTG series of Coating Thickness Gauge have been calibrated, the parameters are saved in the memory and the calibration procedure does not need to be repeated. We do recommed that after numerous hours of operation or if the gauge has not been used for a few days you should check the accuracy using the same calibrated substrate/foil combination previously used to calibrate the gauge.
 
Back to Product Listing
   
Hardness Testers
Ultrasonic Thickness Gauges      Surface Roughness
Coating Thickness      Force Gauges
Vibration Meters      Optical Instruments
  Phase II Plus
21 Industrial Ave.
Upper Saddle River, NJ 07458
Phone: 201-962-7373
Toll Free: 800-526-9087
Fax: 201-962-8353
Click here for a free catalog